Specifications
|
Parameters
|
|
General
|
|
Model
|
T7100 series
|
|
Display
|
§ 5.7 inch (320 x 240 pixels) color TFT LCD
|
|
Power source
|
§ 6VDC AC-DC adapter, AC100V - 240V 50/60Hz, or
§ 4 x 1.5V (AA size) alkaline batteries, non-rechargeable type
|
|
Battery life
|
Approximately 50 measurements with 4 new standard alkaline “AA” batteries and inflating the cuff to 160mmHg at a room temperature of 22°C
|
|
Control buttons (soft key)
|
§ BP
§ AUTO CASP
§ MEMORY
§ SETUP
|
|
Display
|
|
Parameters
|
§ Systolic pressure in mmHg
§ Diastolic pressure in mmHg
§ Central aortic systolic pressure in mmHg
§ Mean arterial pressure in mmHg
§ Pulse rate in BPM (Beats Per Minute)
§ Radial augmentation index in %
§ Radial augmentation pressure in mmHg
§ Peak relative time in mSec (millisecond)
|
|
Pulse Waveform
|
Real-time radial arterial pulse waveform
|
|
Plot area range
|
§ Auto-scalable Y-axis, digital value of 0 to 4395
§ X-axis, 10 seconds
|
|
Blood Pressure & CASP Measurement and Pulse Waveform Acquisition
|
|
Calibration method
|
Oscillometric, performed before use
|
|
Measurement site
|
§ Arm (left or right) for blood pressure measurement
§ Radial artery at the wrist (left or right) for wave acquisition
|
|
Cuff inflation method
|
Automatic, by electric pump
|
|
Cuff deflation method
|
Electronic control valve (modulated)
|
|
Rapid pressure release method
|
Electronic control valve (open)
|
|
Blood pressure measurement time
|
Less than 45 seconds (typically)
|
|
Blood pressure range
|
40 to 280 mmHg
|
|
Measurement accuracy
|
Meets ANSI/AAMI SP10:1992 Standard
|
|
Pulse waveform acquisition device
|
Radial pulse wave acquisition device
|
|
Pulse waveform acquisition method
|
Modified applanation tonometry
|
|
Pulse rate range
|
30 to 180 beats/minute
|
|
Pulse rate accuracy
|
±3%
|
|
Pulse waveform acquisition time
|
10 seconds per block of waveform
|
|
Memory capacity
|
200 sets of blood pressure measurements and CASP readings
|
|
Auto power off time
|
Min. 5 minutes, Max. 15 minutes of non-use (to be defined by user)
|
|
Dimensions and Weight
|
|
Main unit dimensions
|
W160 x D161X H95 mm (W6,3 x D6,3 x H3,7 inch)
|
|
Main unit weight
|
Approximately 0.8 kg with battery (main unit only)
|
|
Environmental
|
|
Operating conditions
|
· 10°C to 40°C
· 15% to 90% relative humidity (non-condensing)
· 80 to 106 kPa atmospheric pressure
|
|
Storage conditions
|
· -20°C to 50°C
· 10% to 95% relative humidity (non-condensing)
|
|
Others
|
|
Cuffs
|
· Regular adult cuff,
for arm circumferences 21 to 30cm (8.3 to 11.8 inches), (included with system)
PART NUMBER: P1500B
· Large adult cuff,
for arm circumferences 29 to 42 cm (11.4 to 16.5 inches) (optional)
PART NUMBER: P1501B
|
|
Patient safety
|
Automatic cuff deflation if any of the following conditions is encountered:
· Cuff pressure exceeds 290 mmHg
· Measurement time exceeds 180 seconds
· Safety timer detects microprocessor failure
|
|
Regulatory
|
|
Electrical safety
|
· IEC60601-1:3.Ed.
|
|
EMC
|
· IEC60601-1-2:2007
· FCC Part 18
|
|
Safety
|
· EN 1060-1: 2002
· EN 1060-3: 1997
|
|
Class
|
· Class IIa, in accordance with EC directive 93/42/EEC (Medical Device Directive) Annex IX rule 10, Patient applied part type BF
|
|
Performance
|
· ANSI/AAMI SP10:1992
|
|
Environmental
|
· MIL-STD810F
|